SSIS package errors while loading delta records.

$
0
0

Hello,

I am getting the following errors, while loading the data into the destination tables.

Please Help me.

Thanks,

Sarika

[Conditional Split 1 [395]] Error: The expression "on "output "Changed Rows" (533)" evaluated to NULL, but the "component "Conditional Split 1" (395)" requires a Boolean results. Modify the error row disposition on the output to treat this result as False (Ignore Failure) or to redirect this row to the error output (Redirect Row).  The expression results must be Boolean for a Conditional Split.  A NULL expression result is an error.

[Conditional Split 1 [395]] Error: SSIS Error Code DTS_E_INDUCEDTRANSFORMFAILUREONERROR.  The "component "Conditional Split 1" (395)" failed because error code 0xC020902B occurred, and the error row disposition on "output "Changed Rows" (533)" specifies failure on error. An error occurred on the specified object of the specified component.  There may be error messages posted before this with more information about the failure.

[SSIS.Pipeline] Error: SSIS Error Code DTS_E_PROCESSINPUTFAILED.  The ProcessInput method on component "Conditional Split 1" (395) failed with error code 0xC0209029 while processing input "Conditional Split Input" (396). The identified component returned an error from the ProcessInput method. The error is specific to the component, but the error is fatal and will cause the Data Flow task to stop running.  There may be error messages posted before this with more information about the failure.

[Table Name [16]] Error: The attempt to add a row to the Data Flow task buffer failed with error code 0xC0047020.

[SSIS.Pipeline] Error: SSIS Error Code DTS_E_PRIMEOUTPUTFAILED.  The PrimeOutput method on component "Table_NM" (16) returned error code 0xC02020C4.  The component returned a failure code when the pipeline engine called PrimeOutput(). The meaning of the failure code is defined by the component, but the error is fatal and the pipeline stopped executing.  There may be error messages posted before this with more information about the failure.

[Table_NM [31]] Error: The attempt to add a row to the Data Flow task buffer failed with error code 0xC0047020.

[SSIS.Pipeline] Error: SSIS Error Code DTS_E_PRIMEOUTPUTFAILED.  The PrimeOutput method on component "Table_NM" (31) returned error code 0xC02020C4.  The component returned a failure code when the pipeline engine called PrimeOutput(). The meaning of the failure code is defined by the component, but the error is fatal and the pipeline stopped executing.  There may be error messages posted before this with more information about the failure.